Emergency shut-offARD-ES-001
Socket weld (SW) connectionPneumatic emergency shut-off valve
Socket weld (SW)
A pneumatic shut-off range with an extended bonnet and a published thermal emergency shut-off temperature.
- Size
- DN 10–200
- Body material
- CF8
- Connections
- Socket weld (SW)
- Temperature
- −196 to +60°C
- Pressure
- PN40 (4.0 MPa nominal)
- Medium
- LO2, LN2, LAr, LCO2, LNG
Engineered for your application
A pneumatic shut-off range with an extended bonnet and a published thermal emergency shut-off temperature.
Sizes and pressure ratings depend on construction, materials and configuration. Confirm the selected pressure-temperature rating with the quotation.
Technical data
The specification, in detail.
| Parameter | Technical specification |
|---|---|
| Size range | DN 10–200 |
| Pressure ratings | PN40 (4.0 MPa nominal) |
| End connections | Socket weld (SW) |
| Medium | LO2, LN2, LAr, LCO2, LNG |
| Temperature range | -196 to +60°C |
| Emergency shut-off temperature | 70°C±5°C |
| Flow direction | High to low |
Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.
End connections
Define the interface.
Shown configuration: Two straight socket-weld ports below the extended neck and pneumatic operator.
| Connection detail | Connection / selection requirement |
|---|---|
| Published connection | Socket weld |
| Connection standard | Not specified on this product page. Confirm the mating standard with the offer. |
| Weld selection | Specify pipe OD, wall thickness/schedule, material and weld preparation. SW and BW are different connections. |
The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.
Materials
From body to seal.
| Component | Material / option |
|---|---|
| Body | CF8 |
| Bonnet | Composite |
| Stem | 06Cr19Ni10 |
| Top / closure element | 06Cr19Ni10+PTFE |
| Gasket | PTFE |
Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.
Selection notes
Defined around your application.
- Socket weld
- Flow direction: High to low
Sizes and pressure ratings depend on construction, materials and configuration. Confirm the selected pressure-temperature rating with the quotation.
“Top / closure element” follows the component designation in the reference material list.
Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.
Arden product datasheet
Product code ARD-ES-001 · Revision 2026-10-28. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.
Download PDFDimensions
Plan the connection.
Dimensions apply to the tabulated version only. Confirm the approved outline drawing for the selected size, rating and connections before installation.
| DN | H | H1 | L | D0 | DI | B | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 10 | 392 | 238 | 60 | 80 | 14.5 | 5 | — |
| 15 | 392 | 238 | 60 | 80 | 18.5 | 5 | — |
| 20 | 459 | 305 | 80 | 80 | 25.5 | 6 | — |
| 25 | 459 | 305 | 80 | 80 | 32.5 | 6 | 4.825 |
| 32 | 474 | 317 | 100 | 80 | 38.5 | 8 | 8.97 |
| 40 | 516 | 338 | 100 | 140 | 45.5 | 8 | 9.05 |
| 50 | 557 | 377 | 130 | 140 | 57.5 | 8 | 11.20 |
| 65 | 567 | 387 | 150 | 140 | 76.5 | 10 | 13 |
| 80 | 698 | 470 | 180 | 220 | 90 | 15 | 27 |
| 100 | 698 | 470 | 200 | 220 | 109 | 15 | — |
| 125 | 782 | 554 | 280 | 220 | 134 | 15 | — |
| 150 | 833 | 605 | 350 | 220 | 160 | 30 | — |
| 200 | 914 | 686 | 400 | 220 | 220 | 20 | 67.5 |
Linear dimensions are in mm and weights in kg unless stated otherwise. Pressure bands in MPa, thread designations and ISO mounting codes are not linear dimensions. Thread designations follow the reference. An em dash means no value is published. Confirm a certified outline drawing for the selected configuration.
Documentation
Product documents
Download the Arden data sheet for ARD-ES-001, or request the outline drawing for your selected configuration.
Product code ARD-ES-001 · Revision 2026-10-28. Illustrations show one configuration; approved order documentation defines the supplied assembly.