Cold-line isolation
Globe, ball and butterfly selections, including pneumatic shut-off arrangements.
Liquid Hydrogen
Liquid-hydrogen service needs its own valve selection. Start with dedicated LH2 constructions and define the complete cold-service assembly.
20 product references · Specifications & datasheets
The application
At temperatures around −253°C, hydrogen service places specific demands on materials, seals and thermal design. The range includes extended-stem and vacuum-jacketed configurations, alongside pressure-reducing, non-return, filtration and relief functions. Each selection follows the actual fluid state and pressure–temperature conditions.
Globe, ball and butterfly selections, including pneumatic shut-off arrangements.
Vacuum-jacketed globe and lift-check configurations for the selected cold-line interface.
Pressure-reducing, filter and safety-valve selections matched to the process duty.
Selection essentials
Products for this application
Only products with liquid hydrogen explicitly stated in their medium data appear here. Published limits and available size/rating combinations vary by configuration.

ARD-CV-006
An angle-pattern LH2 control assembly with bellows stem sealing, an extended cold section and a pneumatic diaphragm actuator with an electro-pneumatic positioner. Trim and actuator are selected from the required flow and pressure cases.
Enquiry range — technical confirmation required

ARD-CV-007
A pneumatic bellows-sealed control valve for LH2 cold boxes and vacuum-insulated lines. The extended cold section separates the process body from the warm diaphragm actuator and positioner.
Enquiry range — technical confirmation required

ARD-ES-006
A pneumatic LH2 shut-off globe assembly with an extended thermal-barrier bonnet. The cold pressure body and warm operating package are selected together for the required isolation sequence.
Enquiry range — technical confirmation required

ARD-GL-015
A compact inline globe configuration with a replaceable valve insert, bellows stem seal and vacuum-jacket attachment flange. The manual upper assembly supports local isolation in space-constrained LH2 equipment.
Enquiry range — technical confirmation required

ARD-CK-012
A compact inline non-return valve for direct installation in LH2 cold boxes and cryogenic pipelines. The enclosed weld-end body has no external actuator and is selected for the required low opening pressure.
Enquiry range — technical confirmation required

ARD-GL-017
An extended-bonnet LH2 globe valve combining bellows and gland packing with a thermal-barrier arrangement. Manual operation is illustrated; insulation and maintenance access are defined around the selected installation.
Enquiry range — technical confirmation required

ARD-GL-010
A manually operated globe-valve reference designed for liquid-hydrogen service down to -253°C. The 316L construction uses an extended upper assembly and a specified polymer sealing system.
Enquiry range — technical confirmation required

ARD-SF-008
A 316L safety-valve reference for liquid-hydrogen pressure protection down to -253°C. Connection size, set pressure and certified relieving capacity are defined for the protected equipment.
Enquiry range — technical confirmation required

ARD-BF-010
A dedicated liquid-hydrogen disc-valve configuration with an extended stuffing box and replaceable sealing-ring arrangement. A manual gearbox is illustrated for local operation.
Enquiry range — technical confirmation required

ARD-BF-011
A dedicated liquid-hydrogen disc-valve configuration with an extended stuffing box and replaceable sealing-ring arrangement. A pneumatic quarter-turn drive is illustrated for remote isolation.
Enquiry range — technical confirmation required

ARD-ST-002
A vacuum-jacketed filter reference for liquid-hydrogen pipework, with an extended insulated body and a replaceable filtration element selected for the process cleanliness requirement.
Enquiry range — technical confirmation required

ARD-ES-005
A lifting-type liquid-hydrogen shut-off assembly combining pneumatic linear actuation, an extended bonnet, a vacuum-jacketed body and a selected bellows sealing arrangement.
Enquiry range — technical confirmation required

ARD-VJ-004
A dedicated liquid-hydrogen non-return assembly with an insulated body and a guided, spring-return lift closure. The passive valve is selected with the flow regime and installation orientation.
Enquiry range — technical confirmation required

ARD-BV-020
A liquid-hydrogen ball-valve enquiry reference for specialized isolation duty. The illustrated extended-stem quarter-turn arrangement is developed around a selected hydrogen-compatible material, seat and pressure-relief design.
Enquiry range — technical confirmation required

ARD-RG-003
A liquid-hydrogen pressure-reducing enquiry reference for a defined upstream and downstream pressure duty. Regulating architecture, sensing arrangement and insulation are selected from the actual process cases.
Enquiry range — technical confirmation required

ARD-VJ-005
A manual liquid-hydrogen globe reference with a metallic vacuum-insulation jacket and full-penetration welded construction. The extended upper assembly combines a selected bellows and spring-energized sealing system.
Enquiry range — technical confirmation required

ARD-GL-014
A manual angle-pattern globe valve for liquid-hydrogen cold lines, with a stainless-steel bellows stem seal, monitoring port and extended bonnet prepared for vacuum-jacket integration.
Enquiry range — technical confirmation required

ARD-CK-011
A self-acting spring-loaded non-return valve with an extended service bonnet for insulated LH2 pipework. The straight-through pressure body and removable upper closure support maintenance planning.
Enquiry range — technical confirmation required

ARD-GL-016
A manual cold-box shut-off valve with a long cryogenic extension and metallic bellows sealing. Weld-in vacuum interfaces and optional thermal intercepts are selected to match the insulated pipework and heat-load budget.
Enquiry range — technical confirmation required

ARD-CK-013
A lift-type LH2 non-return valve with an extended service tower and thermal-barrier construction. Jacketed and non-jacketed selections support cold-box or insulated-line integration.
Enquiry range — technical confirmation required
Adjust the category or technical filters, or tell us what you need.
Product ranges are offered as references for enquiry. Final size, materials, pressure–temperature limits and certification are confirmed for each selected assembly.
Need another configuration? Talk to our teamLiquid Hydrogen
Send the medium, operating conditions and required valve duties. Your application will be included in the enquiry.