Globe valvesARD-GL-010
Connection optionsLiquid-hydrogen globe valve
Threaded / weld ends
A manually operated globe-valve reference designed for liquid-hydrogen service down to -253°C. The 316L construction uses an extended upper assembly and a specified polymer sealing system.
Size and pressure options require technical confirmation.
- Size
- DN 15-100 · project range
- Body material
- 316L stainless steel
- Connections
- Threaded / weld ends
- Operation
- Manual handwheel in illustrated arrangement
- Pressure
- PN40 (4.0 MPa nominal)
- Temperature
- -253 to +80°C
Engineered for your application
A manually operated globe-valve reference designed for liquid-hydrogen service down to -253°C. The 316L construction uses an extended upper assembly and a specified polymer sealing system.
The DN15-100 project range and illustrated manual arrangement require size-specific confirmation. These are not verified availability or approved operating limits for every configuration. Confirm the selected pressure-temperature rating and connection details.
Applications
Liquid HydrogenTechnical data
The specification, in detail.
| Parameter | Technical specification |
|---|---|
| Size range | DN 15-100 · project range |
| Pressure ratings | PN40 (4.0 MPa nominal) |
| Temperature range | -253 to +80°C |
| Medium | LH2 / liquid hydrogen |
| End connections | Threaded / weld ends |
| Operation | Manual handwheel in illustrated arrangement |
| Design service | Liquid hydrogen |
| Size evidence | Manufactured globe-valve project references cover DN15-100; exact illustrated configuration requires confirmation |
Nominal pressure and ASME class are different rating systems. Confirm the pressure–temperature rating for the selected material and design.
End connections
Define the interface.
Shown configuration: a blue manual handwheel, a long white-coated extension and a compact lower body with two opposed metallic end stubs
| Connection detail | Connection / selection requirement |
|---|---|
| Connection options | Threaded / weld ends |
| Interface selection | Specify the end standard, nominal size, pipe dimensions and required mating interface. |
| Thread selection | Threaded alternatives are documented. Confirm thread form, nominal size and sealing method. |
| Weld selection | Welded alternatives are documented. Confirm end preparation and mating-pipe dimensions. |
The illustration shows one configuration. Published connection alternatives are options for enquiry; their availability depends on size, rating, material and design. Installation dimensions come from the drawing, not the illustration.
Materials
From body to seal.
| Component | Material / option |
|---|---|
| Body and bonnet | 316L stainless steel |
| Sealing material | VESPEL / MELDEN - selected grade to confirm |
| Spring | 316 stainless steel |
Published material alternatives are configuration-dependent. H.F. denotes hard facing; the exact grade and material certificates are confirmed with the offer.
Selection notes
Defined around your application.
- Dedicated liquid-hydrogen temperature range
- 316L body and bonnet
- Extended manual upper assembly
- Hydrogen and low-temperature helium inspection documentation specified with the order
| Engineering data | Configuration requirement |
|---|---|
| Liquid-hydrogen qualification | Confirm the selected materials, seal grade, cleanliness, leak-test method, acceptance limits and traceability. |
| Size and connections | Request the size-specific outline drawing and end-connection schedule before installation. |
The DN15-100 project range and illustrated manual arrangement require size-specific confirmation. These are not verified availability or approved operating limits for every configuration. Confirm the selected pressure-temperature rating and connection details.
The DN15-100 span describes manufactured globe-valve project references, not a complete availability matrix for the illustrated manual arrangement.
The nominal pressure is 4.0 MPa. A separately stated body-strength value is not an allowable service-pressure rating.
Published ratings do not establish suitability for every listed medium. Oxygen cleaning, material compatibility, trapped-liquid relief and project approvals are specified for the selected assembly. Liquid-hydrogen and helium service require a separate temperature and material review.
Arden product datasheet
Product code ARD-GL-010 · Revision 2026-10-29. Product illustrations show one configuration; the approved order documentation defines the supplied assembly.
Download PDFDimensions
Plan the connection.
Need installation dimensions?
No numeric dimension table is published for this reference. Request a configuration-specific outline drawing with your enquiry.
Request dimensionsDocumentation
Product documents
Download the Arden data sheet for ARD-GL-010, or request the outline drawing for your selected configuration.
Product code ARD-GL-010 · Revision 2026-10-29. Illustrations show one configuration; approved order documentation defines the supplied assembly.